{"id":772,"date":"2025-01-10T18:24:35","date_gmt":"2025-01-10T17:24:35","guid":{"rendered":"https:\/\/www.ac-acustica.it\/?post_type=servizi&#038;p=772"},"modified":"2026-06-22T15:25:13","modified_gmt":"2026-06-22T13:25:13","slug":"","status":"publish","type":"servizi","link":"https:\/\/www.ac-acustica.it\/en\/servizi\/acustica-edilizia","title":{"rendered":"Building Acoustics","raw":"Building Acoustics"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The <strong>building acoustics<\/strong> service by AC Acustica provides comprehensive solutions for sound insulation and noise control in buildings, ensuring compliance with <strong>passive acoustic requirements<\/strong> and <strong>Minimum Environmental Criteria (CAM)<\/strong> for sustainable construction.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Building Acoustics Services<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Acoustic design according to DPCM 5\/12\/1997:<\/strong> We ensure compliance with passive acoustic requirements in buildings through accurate design of insulation systems for walls, floors, and roofs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Compliance with updated Minimum Environmental Criteria (CAM):<\/strong> We support the design of buildings compliant with CAM requirements, with particular attention to acoustic comfort and environmental sustainability according to the latest regulations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>On-site acoustic testing &#8211; Specialized service:<\/strong> We carry out <strong>comprehensive instrumental verifications<\/strong> to certify compliance with passive acoustic requirements in completed buildings, using methodologies in line with current standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">On-Site Testing of Passive Acoustic Requirements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Testing methodology according to UNI EN ISO 16283:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Facade sound insulation<\/strong> (D2m,nT,w) &#8211; Measurement of insulation performance from external noise<\/li>\n\n\n\n<li><strong>Insulation between units<\/strong> (DnT,w) &#8211; Verification of acoustic separation between adjacent apartments<\/li>\n\n\n\n<li><strong>Impact sound insulation<\/strong> (L&#8217;nT,w) &#8211; Control of impact noise transmission<\/li>\n\n\n\n<li><strong>Service equipment noise<\/strong> (LASmax, LAeq) &#8211; Assessment of noise emissions from building systems<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Testing process:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Measurement planning<\/strong> according to UNI 11367 and UNI EN ISO 16283<\/li>\n\n\n\n<li><strong>Execution of sound measurements<\/strong> using Class 1 instrumentation<\/li>\n\n\n\n<li><strong>Data processing<\/strong> and calculation of acoustic performance indices<\/li>\n\n\n\n<li><strong>Preparation of test certificate<\/strong> with compliance\/non-compliance outcome<\/li>\n\n\n\n<li><strong>Optional acoustic classification<\/strong> of the property unit according to UNI 11367<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Benefits of professional testing:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Official certification<\/strong> of acoustic performance<\/li>\n\n\n\n<li><strong>Legal protection<\/strong> for builders and buyers<\/li>\n\n\n\n<li><strong>Early identification<\/strong> of any non-compliance issues<\/li>\n\n\n\n<li><strong>Support for targeted corrective actions<\/strong> that are effective and efficient<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Building Types<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Residential buildings:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Insulation between adjacent housing units<\/li>\n\n\n\n<li>Control of noise from shared building systems<\/li>\n\n\n\n<li>Compliance with passive acoustic requirements<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Social and public housing:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Application of CAM in public procurement<\/li>\n\n\n\n<li>Optimization of cost vs. acoustic performance<\/li>\n\n\n\n<li>Energy-environmental building certification<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Hospitality structures:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Design for guest acoustic privacy<\/li>\n\n\n\n<li>Insulation from common areas and systems<\/li>\n\n\n\n<li>Control of noise from hospitality activities<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>School buildings:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Classroom acoustics according to UNI 11532<\/li>\n\n\n\n<li>Insulation from gyms and laboratories<\/li>\n\n\n\n<li>Noise control in common areas<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Healthcare facilities:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Design for care and rest environments<\/li>\n\n\n\n<li>Insulation of operating rooms and wards<\/li>\n\n\n\n<li>Control of noise from medical equipment<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Reference Regulations and Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Passive acoustic requirements:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>DPCM 5\/12\/1997<\/strong> &#8211; Passive acoustic requirements for buildings<\/li>\n\n\n\n<li><strong>UNI EN ISO 16283-1,2,3<\/strong> &#8211; On-site measurement of sound insulation<\/li>\n\n\n\n<li><strong>UNI 11367:2010<\/strong> &#8211; Acoustic classification of building units<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Minimum Environmental Criteria (CAM) &#8211; Updated regulation:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>DM 23\/06\/2022<\/strong> &#8211; CAM for public building design services<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Technical standards:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UNI EN ISO 717-1,2<\/strong> &#8211; Evaluation of sound insulation in buildings<\/li>\n\n\n\n<li><strong>UNI 11296<\/strong> &#8211; Installation of windows and doors<\/li>\n\n\n\n<li><strong>UNI 8290<\/strong> &#8211; Residential construction &#8211; technological system<\/li>\n\n\n\n<li><strong>UNI EN 12354<\/strong> &#8211; Calculation of building acoustic performance<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Design Methodology<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Our approach includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Preliminary analysis<\/strong> of regulatory and design constraints<\/li>\n\n\n\n<li><strong>Predictive calculations<\/strong> of acoustic performance according to UNI EN 12354<\/li>\n\n\n\n<li><strong>Material selection<\/strong> and optimal construction systems compliant with CAM<\/li>\n\n\n\n<li><strong>Construction details<\/strong> to avoid acoustic bridges<\/li>\n\n\n\n<li><strong>Technical specifications<\/strong> for correct installation<\/li>\n\n\n\n<li><strong>Testing plan<\/strong> for final performance verification<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Materials and Technologies<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">We design using:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Drywall systems<\/strong> with high acoustic performance<\/li>\n\n\n\n<li><strong>Certified acoustic insulation materials<\/strong> mineral and synthetic CAM-compliant<\/li>\n\n\n\n<li><strong>Sound-absorbing materials<\/strong> for reverberation control<\/li>\n\n\n\n<li><strong>High soundproofing windows and doors<\/strong><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Full Service Phases<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Regulatory analysis<\/strong> and definition of CAM performance objectives<\/li>\n\n\n\n<li><strong>Acoustic design<\/strong> and predictive calculations<\/li>\n\n\n\n<li><strong>Construction phase support<\/strong> and acoustic supervision<\/li>\n\n\n\n<li><strong>Final acoustic testing<\/strong> according to UNI EN ISO 16283<\/li>\n\n\n\n<li><strong>Performance certification<\/strong> and acoustic classification<\/li>\n\n\n\n<li><strong>Post-construction assistance<\/strong> for any corrective measures<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for building acoustic design, testing of passive acoustic requirements, and CAM consultancy in compliance with the latest regulations.<\/p>\n","protected":false,"raw":"<!-- wp:paragraph -->\n<p>The <strong>building acoustics<\/strong> service by AC Acustica provides comprehensive solutions for sound insulation and noise control in buildings, ensuring compliance with <strong>passive acoustic requirements<\/strong> and <strong>Minimum Environmental Criteria (CAM)<\/strong> for sustainable construction.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Building Acoustics Services<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Acoustic design according to DPCM 5\/12\/1997:<\/strong> We ensure compliance with passive acoustic requirements in buildings through accurate design of insulation systems for walls, floors, and roofs.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Compliance with updated Minimum Environmental Criteria (CAM):<\/strong> We support the design of buildings compliant with CAM requirements, with particular attention to acoustic comfort and environmental sustainability according to the latest regulations.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>On-site acoustic testing - Specialized service:<\/strong> We carry out <strong>comprehensive instrumental verifications<\/strong> to certify compliance with passive acoustic requirements in completed buildings, using methodologies in line with current standards.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">On-Site Testing of Passive Acoustic Requirements<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Testing methodology according to UNI EN ISO 16283:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Facade sound insulation<\/strong> (D2m,nT,w) - Measurement of insulation performance from external noise<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Insulation between units<\/strong> (DnT,w) - Verification of acoustic separation between adjacent apartments<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Impact sound insulation<\/strong> (L'nT,w) - Control of impact noise transmission<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Service equipment noise<\/strong> (LASmax, LAeq) - Assessment of noise emissions from building systems<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Testing process:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"ordered\":true,\"className\":\"wp-block-list\"} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Measurement planning<\/strong> according to UNI 11367 and UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Execution of sound measurements<\/strong> using Class 1 instrumentation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Data processing<\/strong> and calculation of acoustic performance indices<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Preparation of test certificate<\/strong> with compliance\/non-compliance outcome<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Optional acoustic classification<\/strong> of the property unit according to UNI 11367<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Benefits of professional testing:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Official certification<\/strong> of acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Legal protection<\/strong> for builders and buyers<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Early identification<\/strong> of any non-compliance issues<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Support for targeted corrective actions<\/strong> that are effective and efficient<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Building Types<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Residential buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Insulation between adjacent housing units<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from shared building systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Compliance with passive acoustic requirements<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Social and public housing:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Application of CAM in public procurement<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Optimization of cost vs. acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Energy-environmental building certification<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Hospitality structures:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design for guest acoustic privacy<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation from common areas and systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from hospitality activities<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>School buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Classroom acoustics according to UNI 11532<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation from gyms and laboratories<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Noise control in common areas<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Healthcare facilities:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design for care and rest environments<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation of operating rooms and wards<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from medical equipment<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Reference Regulations and Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Passive acoustic requirements:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DPCM 5\/12\/1997<\/strong> - Passive acoustic requirements for buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN ISO 16283-1,2,3<\/strong> - On-site measurement of sound insulation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11367:2010<\/strong> - Acoustic classification of building units<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Minimum Environmental Criteria (CAM) - Updated regulation:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DM 23\/06\/2022<\/strong> - CAM for public building design services<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Technical standards:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI EN ISO 717-1,2<\/strong> - Evaluation of sound insulation in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11296<\/strong> - Installation of windows and doors<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 8290<\/strong> - Residential construction - technological system<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN 12354<\/strong> - Calculation of building acoustic performance<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Design Methodology<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Our approach includes:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Preliminary analysis<\/strong> of regulatory and design constraints<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Predictive calculations<\/strong> of acoustic performance according to UNI EN 12354<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Material selection<\/strong> and optimal construction systems compliant with CAM<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Construction details<\/strong> to avoid acoustic bridges<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Technical specifications<\/strong> for correct installation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Testing plan<\/strong> for final performance verification<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Materials and Technologies<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>We design using:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Drywall systems<\/strong> with high acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Certified acoustic insulation materials<\/strong> mineral and synthetic CAM-compliant<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Sound-absorbing materials<\/strong> for reverberation control<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>High soundproofing windows and doors<\/strong><\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Full Service Phases<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list {\"ordered\":true,\"className\":\"wp-block-list\"} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Regulatory analysis<\/strong> and definition of CAM performance objectives<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Acoustic design<\/strong> and predictive calculations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Construction phase support<\/strong> and acoustic supervision<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Final acoustic testing<\/strong> according to UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Performance certification<\/strong> and acoustic classification<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Post-construction assistance<\/strong> for any corrective measures<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for building acoustic design, testing of passive acoustic requirements, and CAM consultancy in compliance with the latest regulations.<\/p>\n<!-- \/wp:paragraph -->"},"excerpt":{"rendered":"<p>Acoustic Insulation, Building Passive Acoustic Requirements, and Minimum Environmental Criteria<\/p>\n","protected":false,"raw":"Acoustic Insulation, Building Passive Acoustic Requirements, and Minimum Environmental Criteria"},"featured_media":985,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"_uag_custom_page_level_css":"","_it_post_content":"<!-- wp:paragraph -->\n<p>Il servizio di <strong>acustica edilizia<\/strong> di AC Acustica offre soluzioni complete per l'isolamento acustico e il controllo del rumore negli edifici, garantendo la conformit\u00e0 ai <strong>requisiti acustici passivi<\/strong> e ai <strong>Criteri Ambientali Minimi (CAM)<\/strong> per l'edilizia sostenibile.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Servizi di Acustica Edilizia<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Progettazione acustica secondo DPCM 5\/12\/1997:<\/strong> Garantiamo il rispetto dei requisiti acustici passivi degli edifici attraverso progettazione accurata di sistemi di isolamento per pareti, solai e coperture.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Conformit\u00e0 ai Criteri Ambientali Minimi (CAM) aggiornati:<\/strong> Supportiamo la progettazione di edifici conformi ai CAM per l'edilizia, con particolare attenzione ai requisiti di comfort acustico e sostenibilit\u00e0 ambientale secondo le pi\u00f9 recenti disposizioni normative.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Collaudi acustici in opera - Servizio specializzato:<\/strong> Effettuiamo <strong>verifiche strumentali complete<\/strong> per certificare il rispetto dei requisiti acustici passivi negli edifici completati, utilizzando metodologie conformi alle normative vigenti.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Collaudo in Opera dei Requisiti Acustici Passivi<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Metodologia di collaudo secondo UNI EN ISO 16283:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Isolamento acustico di facciata<\/strong>&nbsp;(D2m,nT,w) - Misurazione della capacit\u00e0 di isolamento dall'esterno<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Isolamento tra unit\u00e0 immobiliari<\/strong>&nbsp;(DnT,w) - Verifica dell'isolamento tra appartamenti adiacenti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Isolamento acustico di calpestio<\/strong>&nbsp;(L'nT,w) - Controllo della trasmissione del rumore di impatto<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Rumore degli impianti<\/strong>&nbsp;(LASmax, LAeq) - Valutazione delle emissioni sonore degli impianti tecnologici<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Processo di collaudo:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"ordered\":true} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Pianificazione delle misure<\/strong>&nbsp;secondo UNI 11367 e UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Esecuzione rilievi fonometrici<\/strong>&nbsp;con strumentazione di Classe 1<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Elaborazione dati<\/strong>&nbsp;e calcolo degli indici di valutazione acustica<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Redazione certificato di collaudo<\/strong>&nbsp;con esito di conformit\u00e0\/non conformit\u00e0<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Eventuale classificazione acustica<\/strong>&nbsp;dell'unit\u00e0 immobiliare secondo UNI 11367<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vantaggi del collaudo professionale:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Certificazione ufficiale<\/strong>&nbsp;delle prestazioni acustiche<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Tutela legale<\/strong>&nbsp;per costruttori e acquirenti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identificazione precoce<\/strong>&nbsp;di eventuali non conformit\u00e0<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Supporto per interventi correttivi<\/strong>&nbsp;mirati ed efficaci<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Tipologie Edilizie<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Edifici residenziali:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Isolamento tra unit\u00e0 abitative contigue<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Controllo del rumore da impianti condominiali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Conformit\u00e0 ai requisiti acustici passivi<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Edilizia sociale e pubblica:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Applicazione dei CAM negli appalti pubblici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Ottimizzazione del rapporto costo-prestazioni acustiche<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Certificazione energetico-ambientale degli edifici<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Strutture alberghiere:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Progettazione per la privacy acustica degli ospiti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Isolamento da aree comuni e impianti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Controllo del rumore da attivit\u00e0 ricettive<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Edifici scolastici:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Acustica delle aule secondo UNI 11532<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Isolamento da palestre e laboratori<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Controllo del rumore negli spazi comuni<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Strutture sanitarie:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Progettazione per ambienti di cura e riposo<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Isolamento di sale operatorie e degenze<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Controllo del rumore da apparecchiature mediche<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Normative e Standard di Riferimento<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Requisiti acustici passivi:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DPCM 5\/12\/1997<\/strong>&nbsp;- Requisiti acustici passivi degli edifici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN ISO 16283-1,2,3<\/strong>&nbsp;- Misurazioni in opera dell'isolamento acustico<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11367:2010<\/strong>&nbsp;- Classificazione acustica delle unit\u00e0 immobiliari<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Criteri Ambientali Minimi (CAM) - Normativa aggiornata:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DM 23\/06\/2022<\/strong>&nbsp;- CAM per l'affidamento del servizio di progettazione di edifici pubblici<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Standard tecnici:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI EN ISO 717-1,2<\/strong>&nbsp;- Valutazione dell'isolamento acustico in edifici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11296<\/strong>&nbsp;- Posa in opera di serramenti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 8290<\/strong>&nbsp;- Edilizia residenziale - Sistema tecnologico<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN 12354<\/strong>&nbsp;- Calcolo delle prestazioni acustiche degli edifici<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Metodologia di Progettazione<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Il nostro approccio include:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Analisi preliminare<\/strong>&nbsp;dei vincoli normativi e progettuali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Calcolo previsionale<\/strong>&nbsp;delle prestazioni acustiche secondo UNI EN 12354<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Selezione materiali<\/strong>&nbsp;e sistemi costruttivi ottimali per CAM<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Dettagli costruttivi<\/strong>&nbsp;per evitare ponti acustici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Capitolati tecnici<\/strong>&nbsp;per la corretta posa in opera<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Piano di collaudo<\/strong>&nbsp;per la verifica finale delle prestazioni<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Materiali e Tecnologie<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Progettiamo con:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Sistemi a secco<\/strong>&nbsp;ad alte prestazioni acustiche<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Isolanti acustici<\/strong>&nbsp;minerali e sintetici certificati CAM<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Materiali fonoassorbenti<\/strong>&nbsp;per il controllo del riverbero<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Serramenti<\/strong>&nbsp;con elevato potere fonoisolante<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Fasi del Servizio Completo<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list {\"ordered\":true} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Analisi normativa<\/strong>&nbsp;e definizione obiettivi prestazionali CAM<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Progettazione acustica<\/strong>&nbsp;e calcoli previsionali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Supporto in fase di costruzione<\/strong>&nbsp;e direzione lavori acustici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Collaudo acustico finale<\/strong>&nbsp;secondo UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Certificazione prestazioni<\/strong>&nbsp;e classificazione acustica<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Assistenza post-operam<\/strong>&nbsp;per eventuali interventi correttivi<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contatta AC Acustica<\/a><\/strong> per progettazione acustica edilizia, collaudi dei requisiti acustici passivi e consulenza CAM secondo le normative pi\u00f9 aggiornate.<\/p>\n<!-- \/wp:paragraph -->","_it_post_name":"acustica-edilizia","_it_post_excerpt":"Isolamento Acustico, Requisiti Acustici Passivi degli Edifici e Criteri Ambientali Minimi","_it_post_title":"Acustica Edilizia","_en_post_content":"<!-- wp:paragraph -->\n<p>The <strong>building acoustics<\/strong> service by AC Acustica provides comprehensive solutions for sound insulation and noise control in buildings, ensuring compliance with <strong>passive acoustic requirements<\/strong> and <strong>Minimum Environmental Criteria (CAM)<\/strong> for sustainable construction.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Building Acoustics Services<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Acoustic design according to DPCM 5\/12\/1997:<\/strong> We ensure compliance with passive acoustic requirements in buildings through accurate design of insulation systems for walls, floors, and roofs.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Compliance with updated Minimum Environmental Criteria (CAM):<\/strong> We support the design of buildings compliant with CAM requirements, with particular attention to acoustic comfort and environmental sustainability according to the latest regulations.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>On-site acoustic testing - Specialized service:<\/strong> We carry out <strong>comprehensive instrumental verifications<\/strong> to certify compliance with passive acoustic requirements in completed buildings, using methodologies in line with current standards.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">On-Site Testing of Passive Acoustic Requirements<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Testing methodology according to UNI EN ISO 16283:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Facade sound insulation<\/strong> (D2m,nT,w) - Measurement of insulation performance from external noise<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Insulation between units<\/strong> (DnT,w) - Verification of acoustic separation between adjacent apartments<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Impact sound insulation<\/strong> (L'nT,w) - Control of impact noise transmission<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Service equipment noise<\/strong> (LASmax, LAeq) - Assessment of noise emissions from building systems<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Testing process:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"ordered\":true,\"className\":\"wp-block-list\"} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Measurement planning<\/strong> according to UNI 11367 and UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Execution of sound measurements<\/strong> using Class 1 instrumentation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Data processing<\/strong> and calculation of acoustic performance indices<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Preparation of test certificate<\/strong> with compliance\/non-compliance outcome<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Optional acoustic classification<\/strong> of the property unit according to UNI 11367<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Benefits of professional testing:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Official certification<\/strong> of acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Legal protection<\/strong> for builders and buyers<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Early identification<\/strong> of any non-compliance issues<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Support for targeted corrective actions<\/strong> that are effective and efficient<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Building Types<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Residential buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Insulation between adjacent housing units<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from shared building systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Compliance with passive acoustic requirements<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Social and public housing:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Application of CAM in public procurement<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Optimization of cost vs. acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Energy-environmental building certification<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Hospitality structures:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design for guest acoustic privacy<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation from common areas and systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from hospitality activities<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>School buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Classroom acoustics according to UNI 11532<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation from gyms and laboratories<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Noise control in common areas<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Healthcare facilities:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design for care and rest environments<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Insulation of operating rooms and wards<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Control of noise from medical equipment<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Reference Regulations and Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Passive acoustic requirements:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DPCM 5\/12\/1997<\/strong> - Passive acoustic requirements for buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN ISO 16283-1,2,3<\/strong> - On-site measurement of sound insulation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11367:2010<\/strong> - Acoustic classification of building units<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Minimum Environmental Criteria (CAM) - Updated regulation:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>DM 23\/06\/2022<\/strong> - CAM for public building design services<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Technical standards:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI EN ISO 717-1,2<\/strong> - Evaluation of sound insulation in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 11296<\/strong> - Installation of windows and doors<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 8290<\/strong> - Residential construction - technological system<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI EN 12354<\/strong> - Calculation of building acoustic performance<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Design Methodology<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>Our approach includes:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Preliminary analysis<\/strong> of regulatory and design constraints<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Predictive calculations<\/strong> of acoustic performance according to UNI EN 12354<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Material selection<\/strong> and optimal construction systems compliant with CAM<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Construction details<\/strong> to avoid acoustic bridges<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Technical specifications<\/strong> for correct installation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Testing plan<\/strong> for final performance verification<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Materials and Technologies<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p>We design using:<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list {\"className\":\"wp-block-list\"} -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Drywall systems<\/strong> with high acoustic performance<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Certified acoustic insulation materials<\/strong> mineral and synthetic CAM-compliant<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Sound-absorbing materials<\/strong> for reverberation control<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>High soundproofing windows and doors<\/strong><\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Full Service Phases<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list {\"ordered\":true,\"className\":\"wp-block-list\"} -->\n<ol class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Regulatory analysis<\/strong> and definition of CAM performance objectives<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Acoustic design<\/strong> and predictive calculations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Construction phase support<\/strong> and acoustic supervision<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Final acoustic testing<\/strong> according to UNI EN ISO 16283<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Performance certification<\/strong> and acoustic classification<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Post-construction assistance<\/strong> for any corrective measures<\/li>\n<!-- \/wp:list-item --><\/ol>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for building acoustic design, testing of passive acoustic requirements, and CAM consultancy in compliance with the latest regulations.<\/p>\n<!-- \/wp:paragraph -->","_en_post_name":"","_en_post_excerpt":"Acoustic Insulation, Building Passive Acoustic Requirements, and Minimum Environmental Criteria","_en_post_title":"Building Acoustics","edit_language":"en","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"class_list":["post-772","servizi","type-servizi","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Acustica Edilizia | AC Acustica<\/title>\n<meta name=\"description\" content=\"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\/12\/1997, CAM edilizia. Collaudi acustici in Sicilia.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Acustica Edilizia | AC Acustica\" \/>\n<meta property=\"og:description\" content=\"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\/12\/1997, CAM edilizia. Collaudi acustici in Sicilia.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia\" \/>\n<meta property=\"og:site_name\" content=\"AC Acustica\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-22T13:25:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png\" \/>\n\t<meta property=\"og:image:width\" content=\"250\" \/>\n\t<meta property=\"og:image:height\" content=\"250\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia\",\"name\":\"Acustica Edilizia | AC Acustica\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/3.png\",\"datePublished\":\"2025-01-10T17:24:35+00:00\",\"dateModified\":\"2026-06-22T13:25:13+00:00\",\"description\":\"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\\\/12\\\/1997, CAM edilizia. Collaudi acustici in Sicilia.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia#primaryimage\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/3.png\",\"contentUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/3.png\",\"width\":250,\"height\":250},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/acustica-edilizia#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ac-acustica.it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Acustica Edilizia\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#website\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/\",\"name\":\"AC Acustica\",\"description\":\"Progettazione e Consulenza Acustica\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ac-acustica.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#organization\",\"name\":\"AC Acustica\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo-ac.svg\",\"contentUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo-ac.svg\",\"width\":1496,\"height\":507,\"caption\":\"AC Acustica\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Acustica Edilizia | AC Acustica","description":"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\/12\/1997, CAM edilizia. Collaudi acustici in Sicilia.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia","og_locale":"en_GB","og_type":"article","og_title":"Acustica Edilizia | AC Acustica","og_description":"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\/12\/1997, CAM edilizia. Collaudi acustici in Sicilia.","og_url":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia","og_site_name":"AC Acustica","article_modified_time":"2026-06-22T13:25:13+00:00","og_image":[{"width":250,"height":250,"url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia","url":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia","name":"Acustica Edilizia | AC Acustica","isPartOf":{"@id":"https:\/\/www.ac-acustica.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia#primaryimage"},"image":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia#primaryimage"},"thumbnailUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png","datePublished":"2025-01-10T17:24:35+00:00","dateModified":"2026-06-22T13:25:13+00:00","description":"Servizi di acustica edilizia e isolamento acustico. Requisiti acustici passivi DPCM 5\/12\/1997, CAM edilizia. Collaudi acustici in Sicilia.","breadcrumb":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia#primaryimage","url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png","contentUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png","width":250,"height":250},{"@type":"BreadcrumbList","@id":"https:\/\/www.ac-acustica.it\/servizi\/acustica-edilizia#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ac-acustica.it\/"},{"@type":"ListItem","position":2,"name":"Acustica Edilizia"}]},{"@type":"WebSite","@id":"https:\/\/www.ac-acustica.it\/#website","url":"https:\/\/www.ac-acustica.it\/","name":"AC Acustica","description":"Progettazione e Consulenza Acustica","publisher":{"@id":"https:\/\/www.ac-acustica.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ac-acustica.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.ac-acustica.it\/#organization","name":"AC Acustica","url":"https:\/\/www.ac-acustica.it\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.ac-acustica.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/09\/logo-ac.svg","contentUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/09\/logo-ac.svg","width":1496,"height":507,"caption":"AC Acustica"},"image":{"@id":"https:\/\/www.ac-acustica.it\/#\/schema\/logo\/image\/"}}]}},"uagb_featured_image_src":{"full":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false],"thumbnail":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3-150x150.png",150,150,true],"medium":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false],"medium_large":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false],"large":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false],"1536x1536":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false],"2048x2048":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/3.png",250,250,false]},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/www.ac-acustica.it\/en\/author"},"uagb_comment_info":0,"uagb_excerpt":"Isolamento Acustico, Requisiti Acustici Passivi degli Edifici e Criteri Ambientali Minimi","_links":{"self":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/servizi\/772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/servizi"}],"about":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/types\/servizi"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/media\/985"}],"wp:attachment":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/media?parent=772"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}