{"id":774,"date":"2025-01-08T18:33:00","date_gmt":"2025-01-08T17:33:00","guid":{"rendered":"https:\/\/www.ac-acustica.it\/?post_type=servizi&#038;p=774"},"modified":"2026-06-22T15:25:39","modified_gmt":"2026-06-22T13:25:39","slug":"","status":"publish","type":"servizi","link":"https:\/\/www.ac-acustica.it\/en\/servizi\/vibrazioni","title":{"rendered":"Vibrations","raw":"Vibrations"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Our specialized <strong>Vibration<\/strong> service offers comprehensive solutions for the <strong>measurement and control of vibrations<\/strong> in various contexts, using <strong>high-sensitivity calibrated accelerometric chains<\/strong> and ensuring compliance with relevant UNI standards.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Advanced Instrumentation for Vibration Measurement<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>High-sensitivity calibrated accelerometric chains:<\/strong> We provide <strong>calibrated triaxial accelerometers<\/strong> with sensitivity up to <strong>10 V\/G<\/strong>, ensuring precise measurements even for low-amplitude vibrations across different application sectors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Specialized configurations by sector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Industrial accelerometers<\/strong>&nbsp;for machinery and production systems<\/li>\n\n\n\n<li><strong>Seismic sensors<\/strong>&nbsp;for structural and geotechnical monitoring<\/li>\n\n\n\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;for dynamic analysis, including high-frequency applications<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Vibration Measurement and Control Services<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Assessment of vibration impact on buildings and structures:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analysis of structural response to vibrations induced by traffic, machinery, or construction activities<\/li>\n\n\n\n<li>Assessment of structural damage risk according to&nbsp;<strong>UNI 9916:2014<\/strong><\/li>\n\n\n\n<li>Long-term monitoring to evaluate cumulative vibration effects<\/li>\n\n\n\n<li>Correlation with structural and geotechnical parameters<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibration analysis in industrial environments:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Diagnostics of machinery and industrial systems to identify operational issues<\/li>\n\n\n\n<li>Optimization of performance and lifespan of machinery through vibration analysis<\/li>\n\n\n\n<li>Design of isolation systems to reduce vibration transmission<\/li>\n\n\n\n<li>Predictive maintenance based on spectral analysis<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in the transport sector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Assessment of vibration impact from railway and road infrastructure on surrounding buildings<\/li>\n\n\n\n<li>Design of vibration attenuation systems for railways and metro lines<\/li>\n\n\n\n<li>Vibration analysis in vehicles to improve passenger comfort<\/li>\n\n\n\n<li>Monitoring of bridges and viaducts under dynamic loads<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in the building sector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Design of vibration isolation systems for sensitive buildings (hospitals, precision laboratories)<\/li>\n\n\n\n<li>Assessment of vibration comfort in residential and commercial buildings<\/li>\n\n\n\n<li>Modal analysis of structures to identify resonance frequencies and vibration modes<\/li>\n\n\n\n<li>Compliance verification with regulatory limits for human disturbance<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Vibrations in Work Environments According to UNI Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in workplaces according to UNI 9614:1990 and UNI 9614:2017:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to potential receptors caused by vibrations<\/li>\n\n\n\n<li><strong>Triaxial measurements<\/strong>&nbsp;with accelerometers compliant with standards<\/li>\n\n\n\n<li><strong>Established methodologies<\/strong>&nbsp;for data analysis and determination of vibration immission<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in buildings according to UNI 9916:2014:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to occupants in buildings<\/li>\n\n\n\n<li><strong>Classification of vibrations<\/strong>&nbsp;based on intensity and frequency<\/li>\n\n\n\n<li><strong>Definition of acceptability limits<\/strong>&nbsp;for different building uses<\/li>\n\n\n\n<li><strong>Design of mitigation measures<\/strong>&nbsp;tailored to specific cases<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Specialized Application Sectors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Manufacturing industry:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Facilities with high-speed rotating machinery<\/li>\n\n\n\n<li>Production lines with vibrating systems<\/li>\n\n\n\n<li>Metal and material processing plants<\/li>\n\n\n\n<li>Automated transport and handling systems<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Transport infrastructure:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Railway lines<\/li>\n\n\n\n<li>Metro systems and urban transport<\/li>\n\n\n\n<li>Airports and runways<\/li>\n\n\n\n<li>Road bridges and viaducts<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Construction sector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Construction sites using heavy machinery<\/li>\n\n\n\n<li>Demolition and excavation activities<\/li>\n\n\n\n<li>Piling works and special foundations<\/li>\n\n\n\n<li>Structural reinforcement works<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Energy sector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Power plants and cogeneration facilities<\/li>\n\n\n\n<li>Wind farms and turbines<\/li>\n\n\n\n<li>Hydroelectric plants<\/li>\n\n\n\n<li>Pumping and compression stations<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Advanced Analysis Methodologies<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Time-domain analysis:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Statistical analysis<\/strong>&nbsp;of vibration signals<\/li>\n\n\n\n<li><strong>Identification of transient<\/strong>&nbsp;and impulsive events<\/li>\n\n\n\n<li><strong>Correlation<\/strong>&nbsp;with operational and environmental parameters<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Frequency-domain analysis:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>High-resolution FFT spectral analysis<\/strong><\/li>\n\n\n\n<li><strong>Identification of dominant<\/strong>&nbsp;and harmonic frequencies<\/li>\n\n\n\n<li><strong>Modal analysis<\/strong>&nbsp;for structural characterization<\/li>\n\n\n\n<li><strong>Coherence analysis<\/strong>&nbsp;between multiple measurement points<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Reference Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in work environments:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UNI 9614:1990<\/strong>&nbsp;&#8211; Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n\n\n\n<li><strong>UNI 9614:2017<\/strong>&nbsp;&#8211; Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Vibrations in buildings:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UNI 9916:2014<\/strong>&nbsp;&#8211; Criteria for measurement and evaluation of vibration effects on buildings<\/li>\n\n\n\n<li><strong>ISO 4866<\/strong>&nbsp;&#8211; Mechanical vibrations in buildings<\/li>\n\n\n\n<li><strong>DIN 4150<\/strong>&nbsp;&#8211; Structural vibrations<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Specialized Technical Instrumentation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Certified measurement chains:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;with sensitivity up to&nbsp;<strong>10 V\/G<\/strong><\/li>\n\n\n\n<li><strong>Low-noise IEPE signal conditioners<\/strong><\/li>\n\n\n\n<li><strong>Synchronized multi-channel acquisition systems<\/strong><\/li>\n\n\n\n<li><strong>Calibration certificates<\/strong>&nbsp;traceable to national standards<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Specialist Support<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Consulting for the design<\/strong>&nbsp;of anti-vibration systems<\/li>\n\n\n\n<li><strong>Assistance in selecting<\/strong>&nbsp;isolation technologies<\/li>\n\n\n\n<li><strong>Technical training<\/strong>&nbsp;for company staff on regulations<\/li>\n\n\n\n<li><strong>Periodic monitoring<\/strong>&nbsp;of intervention effectiveness<\/li>\n\n\n\n<li><strong>Continuous regulatory updates<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for vibration measurements and specialized consulting in accordance with UNI 9614:1990, UNI 9614:2017, and UNI 9916:2014.<\/p>\n","protected":false,"raw":"<!-- wp:paragraph -->\n<p>Our specialized <strong>Vibration<\/strong> service offers comprehensive solutions for the <strong>measurement and control of vibrations<\/strong> in various contexts, using <strong>high-sensitivity calibrated accelerometric chains<\/strong> and ensuring compliance with relevant UNI standards.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Advanced Instrumentation for Vibration Measurement<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>High-sensitivity calibrated accelerometric chains:<\/strong> We provide <strong>calibrated triaxial accelerometers<\/strong> with sensitivity up to <strong>10 V\/G<\/strong>, ensuring precise measurements even for low-amplitude vibrations across different application sectors.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Specialized configurations by sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Industrial accelerometers<\/strong>&nbsp;for machinery and production systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Seismic sensors<\/strong>&nbsp;for structural and geotechnical monitoring<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;for dynamic analysis, including high-frequency applications<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Vibration Measurement and Control Services<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Assessment of vibration impact on buildings and structures:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Analysis of structural response to vibrations induced by traffic, machinery, or construction activities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Assessment of structural damage risk according to&nbsp;<strong>UNI 9916:2014<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Long-term monitoring to evaluate cumulative vibration effects<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Correlation with structural and geotechnical parameters<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibration analysis in industrial environments:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Diagnostics of machinery and industrial systems to identify operational issues<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Optimization of performance and lifespan of machinery through vibration analysis<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Design of isolation systems to reduce vibration transmission<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Predictive maintenance based on spectral analysis<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in the transport sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Assessment of vibration impact from railway and road infrastructure on surrounding buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Design of vibration attenuation systems for railways and metro lines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Vibration analysis in vehicles to improve passenger comfort<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Monitoring of bridges and viaducts under dynamic loads<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in the building sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design of vibration isolation systems for sensitive buildings (hospitals, precision laboratories)<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Assessment of vibration comfort in residential and commercial buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Modal analysis of structures to identify resonance frequencies and vibration modes<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Compliance verification with regulatory limits for human disturbance<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Vibrations in Work Environments According to UNI Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in workplaces according to UNI 9614:1990 and UNI 9614:2017:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to potential receptors caused by vibrations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Triaxial measurements<\/strong>&nbsp;with accelerometers compliant with standards<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Established methodologies<\/strong>&nbsp;for data analysis and determination of vibration immission<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in buildings according to UNI 9916:2014:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to occupants in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Classification of vibrations<\/strong>&nbsp;based on intensity and frequency<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Definition of acceptability limits<\/strong>&nbsp;for different building uses<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Design of mitigation measures<\/strong>&nbsp;tailored to specific cases<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialized Application Sectors<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Manufacturing industry:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Facilities with high-speed rotating machinery<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Production lines with vibrating systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Metal and material processing plants<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Automated transport and handling systems<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Transport infrastructure:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Railway lines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Metro systems and urban transport<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Airports and runways<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Road bridges and viaducts<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Construction sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Construction sites using heavy machinery<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Demolition and excavation activities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Piling works and special foundations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Structural reinforcement works<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Energy sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Power plants and cogeneration facilities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Wind farms and turbines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Hydroelectric plants<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Pumping and compression stations<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Advanced Analysis Methodologies<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Time-domain analysis:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Statistical analysis<\/strong>&nbsp;of vibration signals<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identification of transient<\/strong>&nbsp;and impulsive events<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Correlation<\/strong>&nbsp;with operational and environmental parameters<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Frequency-domain analysis:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>High-resolution FFT spectral analysis<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identification of dominant<\/strong>&nbsp;and harmonic frequencies<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Modal analysis<\/strong>&nbsp;for structural characterization<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Coherence analysis<\/strong>&nbsp;between multiple measurement points<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Reference Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in work environments:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9614:1990<\/strong>&nbsp;- Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 9614:2017<\/strong>&nbsp;- Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9916:2014<\/strong>&nbsp;- Criteria for measurement and evaluation of vibration effects on buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>ISO 4866<\/strong>&nbsp;- Mechanical vibrations in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>DIN 4150<\/strong>&nbsp;- Structural vibrations<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialized Technical Instrumentation<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Certified measurement chains:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;with sensitivity up to&nbsp;<strong>10 V\/G<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Low-noise IEPE signal conditioners<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Synchronized multi-channel acquisition systems<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Calibration certificates<\/strong>&nbsp;traceable to national standards<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialist Support<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Consulting for the design<\/strong>&nbsp;of anti-vibration systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Assistance in selecting<\/strong>&nbsp;isolation technologies<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Technical training<\/strong>&nbsp;for company staff on regulations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Periodic monitoring<\/strong>&nbsp;of intervention effectiveness<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Continuous regulatory updates<\/strong><\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for vibration measurements and specialized consulting in accordance with UNI 9614:1990, UNI 9614:2017, and UNI 9916:2014.<\/p>\n<!-- \/wp:paragraph -->"},"excerpt":{"rendered":"<p>Measurement and Control of Vibrations to Reduce Impacts on People and Structures<\/p>\n","protected":false,"raw":"Measurement and Control of Vibrations to Reduce Impacts on People and Structures"},"featured_media":987,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"_uag_custom_page_level_css":"","_it_post_content":"<!-- wp:paragraph -->\n<p>Il nostro servizio specializzato in <strong>Vibrazioni<\/strong> offre soluzioni complete per la <strong>misurazione e controllo delle vibrazioni<\/strong> in vari contesti, utilizzando <strong>catene accelerometriche tarate<\/strong> ad alta sensibilit\u00e0 e garantendo la conformit\u00e0 alle normative UNI di riferimento.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Strumentazione Avanzata per Misurazione Vibrazioni<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Catene accelerometriche tarate ad alta sensibilit\u00e0:<\/strong> Disponiamo di <strong>accelerometri triassiali calibrati<\/strong> con sensibilit\u00e0 fino a <strong>10 V\/G<\/strong>, garantendo misurazioni di precisione anche per vibrazioni di bassa ampiezza in diversi settori applicativi.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Configurazioni specializzate per settore:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Accelerometri industriali<\/strong>&nbsp;per macchinari e impianti produttivi<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Sensori sismici<\/strong>&nbsp;per monitoraggio strutturale e geotecnico<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Accelerometri piezoelettrici<\/strong>&nbsp;per analisi dinamiche anche ad alta frequenza<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Servizi di Misurazione e Controllo Vibrazioni<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Valutazione dell'impatto delle vibrazioni su edifici e strutture:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Analisi della risposta strutturale a vibrazioni indotte da traffico, macchinari o attivit\u00e0 di costruzione<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Valutazione del rischio di danni strutturali secondo&nbsp;<strong>UNI 9916:2014<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Monitoraggio a lungo termine per valutare gli effetti cumulativi delle vibrazioni<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Correlazione con parametri strutturali e geotecnici<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Analisi delle vibrazioni in ambito industriale:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Diagnostica di macchinari e impianti industriali per identificare problemi di funzionamento<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Ottimizzazione delle prestazioni e della durata dei macchinari attraverso l'analisi vibrazionale<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Progettazione di sistemi di isolamento per ridurre la trasmissione di vibrazioni<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Manutenzione predittiva basata su analisi spettrali<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni in ambito trasporti:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Valutazione dell'impatto vibrazionale di infrastrutture ferroviarie e stradali sugli edifici circostanti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Progettazione di sistemi di attenuazione delle vibrazioni per linee ferroviarie e metropolitane<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Analisi delle vibrazioni nei veicoli per migliorare il comfort dei passeggeri<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Monitoraggio di ponti e viadotti sotto carico dinamico<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni in ambito edilizio:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Progettazione di sistemi di isolamento dalle vibrazioni per edifici sensibili (ospedali, laboratori di precisione)<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Valutazione del comfort vibrazionale in edifici residenziali e commerciali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Analisi modale di strutture per identificare frequenze di risonanza e modi di vibrazione<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Verifica di conformit\u00e0 ai limiti normativi per il disturbo alle persone<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Vibrazioni in Ambito Lavorativo secondo Normative UNI<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni negli ambienti di lavoro secondo UNI 9614:1990 e UNI 9614:2017:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Valutazione del distubo<\/strong>&nbsp;su potenziali ricettori causato da vibrazioni<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Misurazioni triassiali<\/strong>&nbsp;con accelerometri conformi alla normativa<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Metodologie consolidate<\/strong>&nbsp;per l'analisi dei dati e la determinazione dell'immissione <\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni negli edifici secondo UNI 9916:2014:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Valutazione del disturbo<\/strong>&nbsp;alle persone negli edifici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Classificazione delle vibrazioni<\/strong>&nbsp;in base all'intensit\u00e0 e alla frequenza<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Definizione dei limiti<\/strong>&nbsp;di accettabilit\u00e0 per diverse destinazioni d'uso<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Progettazione di interventi<\/strong>&nbsp;di mitigazione personalizzati<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Settori di Applicazione Specializzati<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Industria manifatturiera:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Stabilimenti con macchinari rotanti ad alta velocit\u00e0<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Linee di produzione con sistemi vibranti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Impianti di lavorazione metalli e materiali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Sistemi di trasporto e movimentazione automatizzati<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Infrastrutture di trasporto:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Linee ferroviarie<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Metropolitane e sistemi di trasporto urbano<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Aeroporti e piste di atterraggio<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Ponti e viadotti stradali<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Edilizia e costruzioni:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Cantieri con utilizzo di macchinari pesanti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Attivit\u00e0 di demolizione e scavo<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Palificazioni e fondazioni speciali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Consolidamento strutturale<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Settore energetico:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Centrali elettriche e impianti di cogenerazione<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Parchi eolici e turbine<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Impianti idroelettrici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Stazioni di pompaggio e compressione<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Metodologie di Analisi Avanzate<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Analisi nel dominio del tempo:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Analisi statistica<\/strong>&nbsp;dei segnali vibrazionali<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identificazione di eventi<\/strong>&nbsp;transitori e impulsivi<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Correlazione<\/strong>&nbsp;con parametri operativi e ambientali<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Analisi nel dominio della frequenza:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Analisi spettrale FFT<\/strong>&nbsp;ad alta risoluzione<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identificazione delle frequenze<\/strong>&nbsp;dominanti e armoniche<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Analisi modale<\/strong>&nbsp;per caratterizzazione strutturale<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Analisi di coerenza<\/strong>&nbsp;tra punti di misura multipli<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Normative di Riferimento<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni negli ambienti di lavoro:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9614:1990<\/strong>&nbsp;- Misura delle vibrazioni negli edifici e criteri di valutazione del disturbo<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 9614:2017<\/strong>&nbsp;- Misura delle vibrazioni negli edifici e criteri di valutazione del disturbo<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrazioni negli edifici:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9916:2014<\/strong>&nbsp;- Criteri di misura e valutazione degli effetti delle vibrazioni sugli edifici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>ISO 4866<\/strong>&nbsp;- Vibrazioni meccaniche negli edifici<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>DIN 4150<\/strong>&nbsp;- Vibrazioni strutturali<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Strumentazione Tecnica Specializzata<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Catene di misura certificate:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Accelerometri piezoelettrici<\/strong>&nbsp;con sensibilit\u00e0 fino a&nbsp;<strong>10 V\/G<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Condizionatori di segnale<\/strong>&nbsp;IEPE a basso rumore<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Sistemi di acquisizione<\/strong>&nbsp;multi-canale sincronizzati<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Certificati di taratura<\/strong>&nbsp;tracciabili agli standard nazionali<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Supporto Specialistico<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Consulenza per la progettazione<\/strong>&nbsp;di sistemi antivibranti<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Assistenza nella selezione<\/strong>&nbsp;di tecnologie di isolamento<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Formazione tecnica<\/strong>&nbsp;del personale aziendale sulle normative<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Monitoraggio periodico<\/strong>&nbsp;dell'efficacia degli interventi<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Aggiornamento normativo<\/strong>&nbsp;continuo<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contatta AC Acustica<\/a><\/strong> per misurazioni di vibrazioni e consulenza specializzata secondo le normative UNI 9614:1990, UNI 9614:2017 e UNI 9916:2014.<\/p>\n<!-- \/wp:paragraph -->","_it_post_name":"vibrazioni","_it_post_excerpt":"Rilievo e Controllo delle Vibrazioni per Ridurre l'Impatto su Persone e Strutture ","_it_post_title":"Vibrazioni","_en_post_content":"<!-- wp:paragraph -->\n<p>Our specialized <strong>Vibration<\/strong> service offers comprehensive solutions for the <strong>measurement and control of vibrations<\/strong> in various contexts, using <strong>high-sensitivity calibrated accelerometric chains<\/strong> and ensuring compliance with relevant UNI standards.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Advanced Instrumentation for Vibration Measurement<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>High-sensitivity calibrated accelerometric chains:<\/strong> We provide <strong>calibrated triaxial accelerometers<\/strong> with sensitivity up to <strong>10 V\/G<\/strong>, ensuring precise measurements even for low-amplitude vibrations across different application sectors.<\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:paragraph -->\n<p><strong>Specialized configurations by sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Industrial accelerometers<\/strong>&nbsp;for machinery and production systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Seismic sensors<\/strong>&nbsp;for structural and geotechnical monitoring<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;for dynamic analysis, including high-frequency applications<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Vibration Measurement and Control Services<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Assessment of vibration impact on buildings and structures:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Analysis of structural response to vibrations induced by traffic, machinery, or construction activities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Assessment of structural damage risk according to&nbsp;<strong>UNI 9916:2014<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Long-term monitoring to evaluate cumulative vibration effects<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Correlation with structural and geotechnical parameters<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibration analysis in industrial environments:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Diagnostics of machinery and industrial systems to identify operational issues<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Optimization of performance and lifespan of machinery through vibration analysis<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Design of isolation systems to reduce vibration transmission<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Predictive maintenance based on spectral analysis<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in the transport sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Assessment of vibration impact from railway and road infrastructure on surrounding buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Design of vibration attenuation systems for railways and metro lines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Vibration analysis in vehicles to improve passenger comfort<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Monitoring of bridges and viaducts under dynamic loads<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in the building sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Design of vibration isolation systems for sensitive buildings (hospitals, precision laboratories)<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Assessment of vibration comfort in residential and commercial buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Modal analysis of structures to identify resonance frequencies and vibration modes<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Compliance verification with regulatory limits for human disturbance<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Vibrations in Work Environments According to UNI Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in workplaces according to UNI 9614:1990 and UNI 9614:2017:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to potential receptors caused by vibrations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Triaxial measurements<\/strong>&nbsp;with accelerometers compliant with standards<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Established methodologies<\/strong>&nbsp;for data analysis and determination of vibration immission<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in buildings according to UNI 9916:2014:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Assessment of disturbance<\/strong>&nbsp;to occupants in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Classification of vibrations<\/strong>&nbsp;based on intensity and frequency<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Definition of acceptability limits<\/strong>&nbsp;for different building uses<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Design of mitigation measures<\/strong>&nbsp;tailored to specific cases<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialized Application Sectors<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Manufacturing industry:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Facilities with high-speed rotating machinery<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Production lines with vibrating systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Metal and material processing plants<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Automated transport and handling systems<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Transport infrastructure:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Railway lines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Metro systems and urban transport<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Airports and runways<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Road bridges and viaducts<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Construction sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Construction sites using heavy machinery<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Demolition and excavation activities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Piling works and special foundations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Structural reinforcement works<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Energy sector:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li>Power plants and cogeneration facilities<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Wind farms and turbines<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Hydroelectric plants<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li>Pumping and compression stations<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Advanced Analysis Methodologies<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Time-domain analysis:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Statistical analysis<\/strong>&nbsp;of vibration signals<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identification of transient<\/strong>&nbsp;and impulsive events<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Correlation<\/strong>&nbsp;with operational and environmental parameters<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Frequency-domain analysis:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>High-resolution FFT spectral analysis<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Identification of dominant<\/strong>&nbsp;and harmonic frequencies<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Modal analysis<\/strong>&nbsp;for structural characterization<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Coherence analysis<\/strong>&nbsp;between multiple measurement points<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Reference Standards<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in work environments:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9614:1990<\/strong>&nbsp;- Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>UNI 9614:2017<\/strong>&nbsp;- Measurement of vibrations in buildings and criteria for disturbance evaluation<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong>Vibrations in buildings:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>UNI 9916:2014<\/strong>&nbsp;- Criteria for measurement and evaluation of vibration effects on buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>ISO 4866<\/strong>&nbsp;- Mechanical vibrations in buildings<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>DIN 4150<\/strong>&nbsp;- Structural vibrations<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialized Technical Instrumentation<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:paragraph -->\n<p><strong>Certified measurement chains:<\/strong><\/p>\n<!-- \/wp:paragraph -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Piezoelectric accelerometers<\/strong>&nbsp;with sensitivity up to&nbsp;<strong>10 V\/G<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Low-noise IEPE signal conditioners<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Synchronized multi-channel acquisition systems<\/strong><\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Calibration certificates<\/strong>&nbsp;traceable to national standards<\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:heading {\"level\":3} -->\n<h3 class=\"wp-block-heading\">Specialist Support<\/h3>\n<!-- \/wp:heading -->\n\n<!-- wp:list -->\n<ul class=\"wp-block-list\"><!-- wp:list-item -->\n<li><strong>Consulting for the design<\/strong>&nbsp;of anti-vibration systems<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Assistance in selecting<\/strong>&nbsp;isolation technologies<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Technical training<\/strong>&nbsp;for company staff on regulations<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Periodic monitoring<\/strong>&nbsp;of intervention effectiveness<\/li>\n<!-- \/wp:list-item -->\n\n<!-- wp:list-item -->\n<li><strong>Continuous regulatory updates<\/strong><\/li>\n<!-- \/wp:list-item --><\/ul>\n<!-- \/wp:list -->\n\n<!-- wp:paragraph -->\n<p><strong><a href=\"https:\/\/www.ac-acustica.it\/contatti\">Contact AC Acustica<\/a><\/strong> for vibration measurements and specialized consulting in accordance with UNI 9614:1990, UNI 9614:2017, and UNI 9916:2014.<\/p>\n<!-- \/wp:paragraph -->","_en_post_name":"","_en_post_excerpt":"Measurement and Control of Vibrations to Reduce Impacts on People and Structures","_en_post_title":"Vibrations","edit_language":"en","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"class_list":["post-774","servizi","type-servizi","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Vibrazioni | AC Acustica<\/title>\n<meta name=\"description\" content=\"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vibrazioni | AC Acustica\" \/>\n<meta property=\"og:description\" content=\"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni\" \/>\n<meta property=\"og:site_name\" content=\"AC Acustica\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-22T13:25:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png\" \/>\n\t<meta property=\"og:image:width\" content=\"250\" \/>\n\t<meta property=\"og:image:height\" content=\"250\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni\",\"name\":\"Vibrazioni | AC Acustica\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/5.png\",\"datePublished\":\"2025-01-08T17:33:00+00:00\",\"dateModified\":\"2026-06-22T13:25:39+00:00\",\"description\":\"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni#primaryimage\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/5.png\",\"contentUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/5.png\",\"width\":250,\"height\":250},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/servizi\\\/vibrazioni#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.ac-acustica.it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Vibrazioni\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#website\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/\",\"name\":\"AC Acustica\",\"description\":\"Progettazione e Consulenza Acustica\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ac-acustica.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#organization\",\"name\":\"AC Acustica\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo-ac.svg\",\"contentUrl\":\"https:\\\/\\\/www.ac-acustica.it\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo-ac.svg\",\"width\":1496,\"height\":507,\"caption\":\"AC Acustica\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ac-acustica.it\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Vibrazioni | AC Acustica","description":"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni","og_locale":"en_GB","og_type":"article","og_title":"Vibrazioni | AC Acustica","og_description":"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.","og_url":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni","og_site_name":"AC Acustica","article_modified_time":"2026-06-22T13:25:39+00:00","og_image":[{"width":250,"height":250,"url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni","url":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni","name":"Vibrazioni | AC Acustica","isPartOf":{"@id":"https:\/\/www.ac-acustica.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni#primaryimage"},"image":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni#primaryimage"},"thumbnailUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png","datePublished":"2025-01-08T17:33:00+00:00","dateModified":"2026-06-22T13:25:39+00:00","description":"Misurazione e controllo vibrazioni con catene accelerometriche tarate. Conformit\u00e0 UNI 9614:1990, 9614:2017, 9916:2014 in Sicilia.","breadcrumb":{"@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ac-acustica.it\/servizi\/vibrazioni"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni#primaryimage","url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png","contentUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png","width":250,"height":250},{"@type":"BreadcrumbList","@id":"https:\/\/www.ac-acustica.it\/servizi\/vibrazioni#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ac-acustica.it\/"},{"@type":"ListItem","position":2,"name":"Vibrazioni"}]},{"@type":"WebSite","@id":"https:\/\/www.ac-acustica.it\/#website","url":"https:\/\/www.ac-acustica.it\/","name":"AC Acustica","description":"Progettazione e Consulenza Acustica","publisher":{"@id":"https:\/\/www.ac-acustica.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ac-acustica.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.ac-acustica.it\/#organization","name":"AC Acustica","url":"https:\/\/www.ac-acustica.it\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.ac-acustica.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/09\/logo-ac.svg","contentUrl":"https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/09\/logo-ac.svg","width":1496,"height":507,"caption":"AC Acustica"},"image":{"@id":"https:\/\/www.ac-acustica.it\/#\/schema\/logo\/image\/"}}]}},"uagb_featured_image_src":{"full":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false],"thumbnail":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5-150x150.png",150,150,true],"medium":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false],"medium_large":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false],"large":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false],"1536x1536":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false],"2048x2048":["https:\/\/www.ac-acustica.it\/wp-content\/uploads\/2025\/01\/5.png",250,250,false]},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/www.ac-acustica.it\/en\/author"},"uagb_comment_info":0,"uagb_excerpt":"Rilievo e Controllo delle Vibrazioni per Ridurre l'Impatto su Persone e Strutture","_links":{"self":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/servizi\/774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/servizi"}],"about":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/types\/servizi"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/media\/987"}],"wp:attachment":[{"href":"https:\/\/www.ac-acustica.it\/en\/wp-json\/wp\/v2\/media?parent=774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}